Remote Reset
Description:
The CMCP570A Solid State Temperature Monitors are compatible
with temperature inputs from dual purpose sensors (vibration
and temperature), and they provide a 4-20 mA output proportional
to the overall measurement. Each unit provides power for
the associated transducer, processes the signal to determine
overall amplitude, and outputs a 4-20 mA dc current that
is proportional to a user specified range such as 0-250
Deg. F. Combining monitors with an existing PLC or DCS system
results in a high density, low cost monitoring system. The
alarm feature functions as a complete single channel monitor
that includes alert and danger alarms, and output relays.
Buffered Output:
A BNC connector mounted on the front of the unit provides
access to the buffered transducer output signal. This includes
both the unfiltered vibration signal, and the DC bias voltage.
Portable test equipment or analyzers like SKF-CM's MicrologTM
can be connected to this output without disturbing other
system outputs.
Fault Detection:
On board fault detection circuitry continuously monitors
the transducer for normal operation. If a fault occurs,
the output current is reduced to 2 mA to indicate the fault
to the readout system. A red LED on the front of the unit
is turned on to provide a local indication of the fault.
Alarms:
The CMCP570A Series Monitors have two independent set points,
with LED alarm indicators and output relay contacts (Alert
and Danger). Set points are adjustable via potentiometer,
from 0 to 110% of full scale. Each has an adjustable delay
of 1 to 10 seconds. Relay contacts can be independently
configured by the user for either Normally Open (NO) (Standard)
or Normally Closed (NC) operation. Relays are normally de-energized
and can be configured for latching or non-latching (standard)
operation. Latched alarms may be reset locally or by remote
contact closure. SPST Relay contacts are rated 5 Amps @
30 Vdc or 250 Vac for resistive loads. The monitors also
have set point multiplication of 3X via contact closure
(2X available).
Displays And Assemblies:
Various display options, NEMA and explosion-proof enclosures,
and assembled multi-channel systems are available. Consult
your sales representative.
Electrical Specifications:
Power: +24 Vdc @ 45 mA max. (30 mA typical at 2 full scale
output). Reverse polarity and transient protection included.(With
the Alarm/Relay option installed: 75 mA max.)
Frequency Response (Without optional filters): (-3 dB) 2
Hz to 20 kHz.
Buffered Output: BNC Connector 0-20 kHz.
Accuracy: 0.5 % of Full Scale Range.
Output: 4-20 mA proportional to the full scale range.
Maximum Load: 600 Ohms Resistive.
Case: Isolated.
Environmental Specifications:
Operating Temp.: -20oC to +80oC (-4oF to +176oF).
Storage Temp.: -55oC to +125oC (-67oF to +257oF).
Relative Humidity: 0 - 95% Non-Condensing.
Mounting:
32 mm (G style) or 35 mm (T style) DIN Rail.
Ordering Example:
To order a solid state temperature monitor that accepts
input from a dual purpose sensor, such as the SKF-CM CMSS793T-3,
or the Wilcoxon 797T-1, with a Full Scale of 0-250 Deg.
F Detection, specify Part Number: CMCP570A-01-01.
NOTES:
1.The Full Scale option specified at order entry is used
by the factory for initial calibration. However, several
other ranges can be jumper selected in the field.
2.Transducer and Full Scale options not listed in the above
table are available. Contact your sales representative.