Sales Technology, Inc. (STI) specializes in Vibration Monitoring and is a manufacturer of comprehensive Condition Monitoring and Machine Protection Solutions, and has been producing quality vibration sensors and monitoring products since 1989.
CMCP535A Vibration Displacement Monitors
Features:
  • Low Cost
  • Small Size
  • DIN Rail Mount
  • Voltage Output Velocity Transducer Input
  • 4-20 mA Output
  • Fault Detection
  • Buffered Transducer Output
  • Filter Option
  • Alert and Danger Alarms
  • Trip Multiply
  • Remote Reset

    Description:
    The CMCP535A Vibration Displacement Monitors are compatible with voltage output velocity transducer inputs, and they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 5 mils peak to peak. Combining monitors with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. The alarm feature functions as a complete single channel monitor that includes alert and danger alarms, and output relays.

    Buffered Output:
    A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers like SKF-CM's MicrologTM can be connected to this output without disturbing other system outputs.

    Fault Detection:
    On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to 2 mA to indicate the fault to the readout system. A red LED on the front of the unit is turned on to provide a local indication of the fault.

    Filters:
    For applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.

    Alarms:
    The CMCP535A Vibration Displacement Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads. The monitors also have set point multiplication of 3X via contact closure (2X available).

    Displays And Assemblies:
    Various display options, NEMA and explosion-proof enclosures, and assembled multi-channel systems are available. Consult your sales representative.

    Electrical Specifications:
    Power: +24 Vdc @ 45 mA max. (30 mA typical at 2 full scale output). Reverse polarity and transient protection included.(With the Alarm/Relay option installed: 75 mA max.)
    Frequency Response (Without optional filters): (-3 dB) 2 Hz to 2 kHz.
    Buffered Output: BNC Connector 0-20 kHz.
    Accuracy: 0.5 % of Full Scale Range.
    Output: 4-20 mA proportional to the full scale range.
    Maximum Load: 600 Ohms Resistive.
    Case: Isolated.

    Environmental Specifications:
    Operating Temp.: -20oC to +80oC (-4oF to +176oF).
    Storage Temp.: -55oC to +125oC (-67oF to +257oF).
    Relative Humidity: 0 - 95% Non-Condensing.

    Mounting: 32 mm (G style) or 35 mm (T style) DIN Rail.

    Ordering Example:

    To order a vibration displacement monitor that accepts input from a 100 mV/in/sec velocity transducer, with a Full Scale of 5 mils peak to peak, specify Part Number: CMCP535A-100V-01.
    NOTES:
    1.To order factory installed 4-pole filter modules, add the appropriate suffix to the basic part number:
    Example: adding suffix -L500 specifies a 4-pole low-pass filter with a corner frequency of 500 Hz (30,000 cpm). Adding suffix - H40 specifies a 4-pole High-Pass filter with a corner frequency of 40 Hz (2400 cpm). Up to two filter modules may be specified. Filter modules can be field installed. If you are unsure about your filter needs, need higher order filters or a band-pass response, consult the factory or your regional sales office for assistance in specifying the correct option numbers.
    2.The Full Scale option specified at order entry is used by the factory for initial calibration. However, several other ranges can be jumper selected in the field.
    3.Transducer and Full Scale options not listed in the above table are available. Contact your sales representative.


  • Vibration Monitoring | Infrared Imaging | Grease Analysis | Accelerometers | Laser Alignment | Ultrasonic Detection | Training | Accessories